Start
Help
Search
Toggle Dropdown
Advanced Search
Log in
Register
Page Loading, Please Wait...
Loading...
Results
1 item(s) found
Permit
License
Project
Violation
Work Order
Selected Items
All items
(Select an action)
Export
Add to Watch List
Remove from Watch List
Pay
All
Permits
Licenses
Projects
Violations
Recently Modified
Filing Date (Newest First)
Filing Date (Oldest First)
Person/Business (Z-A)
Person/Business (A-Z)
10
20
50
100
200
1010 Governor Nicholls St
·
VCC General Work
·
Permit #23-23490-VCGEN
·
Ref Code:YGW1JS
View
Print Summary
Add to Watch List
Type:
VCC General Work
Status:
Permit Picked Up
Date Filed:
8/25/2023
Closed:
No
Description::
To address violations cited in case 21-08532-DBNVCC, per attached materials stamped VCC approved 11/09/2023: Remove vegetation from masonry. Cut vegetation down and apply a weed and grass killer. Remove dead roots after 1-2 days. Install new VCC mortar (formula attached) as needed where deteriorated Repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Sound all existing stucco and remove delaminated material. Apply VCC formula stucco where missing and/or removed, according to VCC standard detail sheet (attached). Lath or adherents of any kind are prohibited unless preapproved by VCC staff prior to installation. Replace cracked roof tiles as needed to match existing. Replace six pairs of shutters to match existing in type, style, size, dimension, reveal, operation, attachment, profile, reveal, color, material and finish. Submit complete scaled and dimensioned shop drawings to VCC staff for final review and approval prior to fabrication and installation. Replace two (2) unpermitted light fixtures on side elevation of main building with new NICOR 11522 double cylinder bullet fixtures, painted to match the adjacent surface to minimize visibility. All wiring shall be placed in conduits. All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. All fixtures shall use lamps with the following cri
Expires:
5/9/2024
Division:
VCC
Subdivision:
French Quarter
Council District:
C
Area:
0
Next Status:
Permit Finaled
Next Status Date:
12/25/2023
Next Inspection:
Inspection Date:
Next Inspector:
Total Fees:
0.00
Unpaid Fees:
0.00
Final Date:
Days Open:
258
Days Issued:
182
Filing Date:
8/25/2023
Lead Staff:
Noah A Epstein, Erin Vogt
«
»
Page Loading, Please Wait...
Loading...
Account Required
×
You need an account to favorite records.
Account Required
×
You need an account to pay.
Selection
×
You need to select a record to perform this action.
Too many items
×
This action is limited to 200 records.
Select
×
You need to select an action.