Description:: Burgundy elevation below first-floor window sill & entire Barrack elevation:
To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached). Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. LATH OF ANY KIND IS NOT TO BE APPLIED UNDER ANY CIRCUMSTANCES.
All work must conform to the VCC policies & guidelines. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, and/or VCC mortar specified in the permit and associated attachments will result in a VCC Stop Work Order, VCC violation, and mandated repair of improper work.
Expires: 1/15/2023
Division: VCC
Subdivision: French Quarter,French Quarter
Council District: C,
Area: 0
Next Status: Permit Finaled
Next Status Date: 8/30/2022