1212 Valence St
·
Residential Re-Roofing
·
Permit #26-19246-ROOF
·
Ref Code:RDFADU
View
Print Summary
Add to Watch List
Type:
Residential Re-Roofing
Status:
Finaled
Date Filed:
6/30/2026
Closed:
Yes
Description::
1. Removal and Disposal: Remove, haul, tear-off, and dispose of one layer of the existing roof. 2. Roof Deck Nailing: Nail the existing roof deck with 8d ring-shank nails spaced at 4 inches on center per F-RR-3 standards. 3. Deck Sealing: Install deck tape on decking seams across the entire roof to enhance sealing. 4. Waterproofing: Install Weatherlock Owens Corning Ice & Water Shield per local building codes. Use WeatherLock® Mat Self-Sealing Ice & Water Barrier in valleys and around openings. 5. Underlayment: Install double layer of RhinoRoof synthetic underlayment for additional moisture and wind-driven rain protection. This creates a bond break between the shingles and the Ice-and-Water shield. 6. Drip Edge: Replace the existing drip edge with a new fortified drip edge that extends 1/2 inch below the sheathing and a minimum of 2 inches back onto the roof. Secure the drip edge to the roof deck with mechanical fasteners at a maximum of 4inches apart. 7. Starter Shingles: Install Owens Corning double-sided starter shingle rolls along the entire perimeter of the roof. 8. Shingles: Use Owens Corning™ DURATION® 9. Hip & Ridge Shingles: Install Owens Corning™ PROEDGE® Hip & Ridge Shingles. 10. Ridge Vent: Install Owens Corning ridge vent/ eave vents for proper ventilation. 11. Bullet Boots12. Flashing: Once all applicable photos have been uploaded, please email Inspections@nola.gov requesting permit closure. PHOTOS REQUIRED 4 geotagged photos (one from each side) s
Expires:
12/30/2026
Division:
SP
Subdivision:
Uptown
Council District:
B
Area:
0
Next Status:
Next Status Date:
Next Inspection:
Inspection Date:
Next Inspector:
Total Fees:
60.00
Unpaid Fees:
0.00
Final Date:
8/26/2026
Days Open:
57
Days Issued:
51
Filing Date:
6/30/2026
Lead Staff:
«
»
Page Loading, Please Wait...
Loading...
Account Required
×
You need an account to favorite records.
Account Required
×
You need an account to pay.
Selection
×
You need to select a record to perform this action.
Too many items
×
This action is limited to 200 records.
Select
×
You need to select an action.