1201 Decatur St
·
VCC General Work
·
Permit #18-28166-VCGEN
·
Ref Code:QTY0X7
View
Print Summary
Add to Watch List
Type:
VCC General Work
Status:
Permit Finaled
Date Filed:
9/5/2018
Closed:
Yes
Description::
To repair/replace existing downspouts to match existing To repair balcony as follows: Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5/4x4 wood T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). Remove all existing, unpermitted and/or unshielded light fixtures Install six (6) Kichler 9834WH fixtures to the underside of the balcony in locations of existing fixtures Fixtures shall be painted or prefinished white to match adjacent building surface. All wiring shall be placed in conduits All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb NOTE: All painting and associated prep work to be permitted separately. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will ca
Expires:
3/20/2019
Division:
VCC
Subdivision:
French Quarter
Council District:
C
Area:
0
Next Status:
Next Status Date:
Next Inspection:
Inspection Date:
Next Inspector:
Total Fees:
0.00
Unpaid Fees:
0.00
Final Date:
2/25/2019
Days Open:
173
Days Issued:
157
Filing Date:
9/5/2018
Lead Staff:
Nicholas G Albrecht
«
»