1317 Ursulines Ave
·
HDLC COA
·
Ref Code:MBY6MX
View
Print Summary
Add to Watch List
Type:
HDLC COA
Status:
Permit Expired Due to Inactivity
Date Filed:
1/26/2023
Closed:
Yes
Description::
1317 Ursulines rear deck permit description I am requesting an, “after the fact” permit on an existing deck. The deck is built with (PT), pressure treated lumber, Trex composite decking, Simpson joist hangers, steel lag bolts and steel carriage bolts and exterior grade nails and screws. The deck is anchored to the existing rear CMU brick/filled wall at 18” (℄), on center, at the mortar joints, with a PT 2x12 home ledger board. The four outer and four inner 2x12 rim joists are stagger, notched and anchored with Simpson joist hangers and 5/8” carriage bolts at the home ledger board as well as the four 4x6 support piers. All PT 2x12 deck floor joists are anchored with Simpson joist hangers at both ends, are laid out on a 10” ℄ and have PT 2x12 staggered bridging throughout. The Trex composite deck boards are attached with the trex manufactures clip system. The balustrades are made of PT lumber. They consist of four 4x6 posts, four 4x4 posts, two 2x4 posts, 2x4 base rail, top rail and cap rail and 2x2 square balusters. The base rail height is less than 4” from the Trex composite decking, the balusters are at 4” ℄ and the 2x4 house posts are anchored in to the existing CMU bricks with steel lag bolts. The stairs are made of 1/4” steel and the stair railings are made of PT lumber and match the deck balustrades. The four PT 4x6 support posts are set in an 8” diameter form, 4’ deep cement filled holes. The deck sits more than 1 1/2’ from the rear property line and the nearest buil
Expires:
7/26/2023
Division:
HDLC
Subdivision:
Treme - Lafitte
Council District:
C
Area:
0
Next Status:
Next Status Date:
Next Inspection:
Inspection Date:
Next Inspector:
Total Fees:
500.00
Unpaid Fees:
500.00
Final Date:
11/12/2025
Days Open:
1020
Days Issued:
0
Filing Date:
1/26/2023
Lead Staff:
Michala Daniels
«
»