1101 Decatur St [Style And Style]
·
VCC General Work
·
Permit #14-12781-VCGEN
·
Ref Code:8NBA1Y
View
Print Summary
Add to Watch List
Type:
VCC General Work
Status:
Permit Finaled
Date Filed:
4/21/2014
Closed:
Yes
Description::
To remove graffiti from masonry walls utilizing “Diedrich 505 Special Coating Stripper” per approved specification sheets stamped 04/24/14, manufacturer’s specifications, and the following specifics: • Prepare a test panel or test a small, unobtrusive section of the wall in situ. • Pre-wet the surface as a precaution against solubilized paint being absorbed via capillary reaction by and staining porous masonry surfaces. The surface should not be allowed to dry at any time during the cleaning. • Rinse the treated area thoroughly, removing any residual cleaning products and solubilized paint. • If pressure washers are used, pressure should not exceed 500 psi. Always rinse surfaces from top to bottom using a 45 degree fan-tip nozzle. Maintain a minimum distance of 18 inches between the nozzle tip and the masonry surface. Use the lowest possible pressure to achieve desired results. • Once test is complete, applicant should contact the VCC for a visual inspection. If the results are satisfactory, VCC staff will direct applicant to proceed as necessary to remove all graffiti utilizing the methodology outlined above. Note: Metal brushes or scrapers should not be used. Plastic scrapers and nylon or natural bristle brushes are acceptable. Mechanical sanders shall not be used. This permit prohibits the application of the following exterior coating materials and paints: sealers, ceramic coatings/paints, elastomeric coatings/paints, waterproofing/water repellent coating
Expires:
10/23/2014
Division:
VCC
Subdivision:
French Quarter
Council District:
C
Area:
0
Next Status:
Next Status Date:
Next Inspection:
Inspection Date:
Next Inspector:
Total Fees:
0.00
Unpaid Fees:
0.00
Final Date:
6/9/2014
Days Open:
49
Days Issued:
46
Filing Date:
4/21/2014
Lead Staff:
«
»
Page Loading, Please Wait...
Loading...
Account Required
×
You need an account to favorite records.
Account Required
×
You need an account to pay.
Selection
×
You need to select a record to perform this action.
Too many items
×
This action is limited to 200 records.
Select
×
You need to select an action.