617 Chartres St
·
Renovation (Non-Structural)
·
Ref Code:4EN3F2
View
Print Summary
Add to Watch List
Type:
Renovation (Non-Structural)
Status:
Application Submitted
Date Filed:
6/28/2021
Closed:
No
Description::
Per attached materials stamped VCC approved 11/1/2021, to address VCC violation case # 21-034301-DBNVCC: To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Repair/replace deteriorated stucco using VCC stucco formula (attached) Lath of any kind is prohibited unless preapproved by VCC staff prior to installation. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. Repair roof damage at overhang on rear per attached drawing. Remove abandoned wiring as needed. Install remaining wiring in conduits. All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery purlins at the deck line, and painted to match the adjacent surfaces. Remove vegetation from masonry. Cut vegetation down and apply a weed and grass killer. Remove dead roots after 1-2 days. Install new VCC mortar (formula attached) as needed where deteriorated Repair louvered shutters to match existing.
Expires:
12/28/2021
Division:
SP
Subdivision:
French Quarter
Council District:
C
Area:
0
Next Status:
Application Review
Next Status Date:
7/1/2021
Next Inspection:
Inspection Date:
Next Inspector:
Total Fees:
165.00
Unpaid Fees:
165.00
Final Date:
Days Open:
932
Days Issued:
0
Filing Date:
6/28/2021
Lead Staff:
«
»