630 Bourbon St
·
VCC General Work
·
Permit #22-15453-VCGEN
·
Ref Code:403R84
View
Print Summary
Add to Watch List
Type:
VCC General Work
Status:
Permit Picked Up
Date Filed:
5/27/2022
Closed:
Yes
Description::
To address long-standing VCC violations cited in case 20-20954-VCCNOP, per attached materials stamped VCC approved 07/26/2022. Courtyard infill structure prescribed, see attached engineer's report. Retain mechanical equipment at rear per attached plan and equipment schedule. Remove plexiglass and install tempered safety glass. Repair all millwork as needed to match existing in size, material, color, profile, reveal, dimension, exposure, function and operation. Reconstruct roof over gallery, install new galvanized standing seam roof, beaded wood tongue and groove decking, and repair existing ornamental fascia. All structure to remain. Remove deteriorated floor boards, stringers, and fascia boards from gallery. Install new 3"x4" beaded stringers, 5/4x4 wood T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). Replace light fixtures with new Kuzco Nordic EW3105 wall sconces. Fixtures shall be painted or prefinished to match adjacent building surface. All wiring shall be placed in conduits. All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb
Expires:
1/26/2023
Division:
VCC
Subdivision:
French Quarter,French Quarter
Council District:
C,
Area:
0
Next Status:
Next Status Date:
Next Inspection:
Inspection Date:
Next Inspector:
Total Fees:
0.00
Unpaid Fees:
0.00
Final Date:
Days Open:
60
Days Issued:
0
Filing Date:
5/27/2022
Lead Staff:
Erin Vogt
«
»
Page Loading, Please Wait...
Loading...
Account Required
×
You need an account to favorite records.
Account Required
×
You need an account to pay.
Selection
×
You need to select a record to perform this action.
Too many items
×
This action is limited to 200 records.
Select
×
You need to select an action.