605 Bourbon St
·
VCC General Work
·
Permit #19-08359-VCGEN
·
Ref Code:2CM4N7
View
Print Summary
Add to Watch List
Type:
VCC General Work
Status:
Permit Expired
Date Filed:
4/1/2019
Closed:
Yes
Description::
To renovate the Bourbon St. elevation of the 605-609 Bourbon St. building as per Architecture Committee approval of 05/14/19 and materials stamped VCC approved 06/21/19. Work includes: • Replacement of existing ten (10) lite French doors with new eight (8) lite, wood, true divided lite French doors to exactly match existing French doors at 601-603 Bourbon • Replacement of existing two (2) lite French doors at 605 Bourbon with new eight (8) lite, wood, true divided lite French doors to exactly match existing French doors at 601-603 Bourbon • Removal of all existing, unpermitted and/or unshielded light fixtures • Installation of two (2) Konial 5” outdoor wall sconces to the wall above the door openings at 605 and 609 Bourbon • Fixtures shall be painted or prefinished to match adjacent building surface. • All wiring shall be placed in conduits • All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. • All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, or exposures as specified in permit will result in a VCC violation and mandated repair of improper work.
Expires:
12/24/2019
Division:
VCC
Subdivision:
French Quarter
Council District:
C
Area:
0
Next Status:
Next Status Date:
Next Inspection:
Inspection Date:
Next Inspector:
Total Fees:
0.00
Unpaid Fees:
0.00
Final Date:
Days Open:
1047
Days Issued:
963
Filing Date:
4/1/2019
Lead Staff:
Nicholas G Albrecht
«
»