1001 S Peters St
·
HDLC COA
·
Permit #24-00865-HDLC
·
Ref Code:0L8GMB
View
Print Summary
Add to Watch List
Type:
HDLC COA
Status:
Finaled
Date Filed:
1/12/2024
Closed:
Yes
Description::
Remove all roofing materials and properly dispose of. Provide two (2) layers of insulation, one which is 2" and the top layer of 1.5” (LTTR equals R- 21.1 or per the local code) polyisosanurate insulation (joints staggered). Adhere insulation with low rise adhesive (thickness as denoted above) adhered in accordance to the manufacturer's recommendations, the attached ‘Low Rise Adhesive Securement Table’ and in accordance with Factory Mutual. Refer to Factory Mutual Loss Prevention Data Sheets 1-28 and 1-29 (most current edition) for the adhesion recommendations based upon the zone and building height. The low-rise adhesive is to rise above the board stock 1/8” to ¼” above the substrate. Adjustment to the height of the rise may be necessary. The surface must be free of loose gravel, dirt, debris, oil, grease, and standing water. A pull test is required to confirm the adhesion. Furnish and install 2-ply, white granular surfaced, torch applied, SBS modified bitumen roofing system in strict accordance with drawings and specifications as approved by Manufacturer. System to consist of the one layer of SBS Glass Torch Base and one layer of the SBS Ultra White FR Torch. The metal edge detail at the penthouse is to consist of a 4” x 3” 24 Ga. pre-finished (same color as existing) drip edge using a 22 gauge continuous cleat complete with backer plates and cover plates. A non-drying butyl sealant is to be sandwiched between backer plate and edging and between the edging a
Expires:
7/12/2024
Division:
HDLC
Subdivision:
Lower Garden District
Council District:
B
Area:
0
Next Status:
Next Status Date:
Next Inspection:
Final HDLC
Inspection Date:
1/28/2025
Next Inspector:
Daniel Syal
Total Fees:
0.00
Unpaid Fees:
0.00
Final Date:
1/28/2025
Days Open:
381
Days Issued:
381
Filing Date:
1/12/2024
Lead Staff:
Yvette Tyler
«
»