GIS Addressing | Resolved | Subdivision into two lots need to be done, no lots of record seen. |
Permit Intake | Resolved | Permit Intake - Please provide a detailed construction contract signed by the current property owner and a licensed contractor registered with the Louisiana State License Board for Contractors. This contract needs to include the cost of all labor and all materials with a cost breakdown of the work to be done. Note: Contract must be signed and dated by Owner and Contractor with names printed under the signatures. |
Permit Intake | Resolved | Architectural Plans Required: One set of complete DIGITAL plans of the building which completely detail the work must be submitted with the digital stamped Seal of a Louisiana registered Architect or Civil Engineer as per Section R106.1 of the IRC
2015 ed. Please combine all drawings into a single PDF file.
PLEASE VISIT http://www.nola.gov/safety-and-permits/policies-and-guidelines/standards-for-digital-submission. |
Permit Intake | Resolved | Permit Intake - This appears to be a substantial improvement to the property and, as such, an Elevation Certificate is required for this permit application. The Elevation Certificate must bear the live seal of a Louisiana registered land surveyor and dated within the last six (6) months. This must be on the Safety & Permits three-part form dated September 30, 2016. |
Permit Intake | Resolved | Permit Intake - Please submit a survey from a land surveyor or a civil engineer which shows the location and dimensions of the lot. |
Permit Intake | Resolved | Permit Intake - Please upload your plumbing riser diagram as a PDF document. The SWBNO plumbing department will review your uploaded riser diagram. |
Zoning | Resolved | This property is located within the University Area Off-street Parking Overlay District. Please verify compliance with
https://nolagov-my.sharepoint.com/:b:/g/personal/claire_byun_nola_gov/EcgCpy1yYqlEvAj8Xcu-CZgBUGO9kugoLbb7FuwxEwGtCw?e=husxAm
- Alternatively, if a hardship exists, you may seek a variance from the Board of Zoning Adjustments. Contact CPC for more information at cpcinfo@nola.gov or 504-658-7033. For application materials and approval criteria please see this link: https://www.nola.gov/onestop/building/planning-project/variances/ |
Zoning | Withdrawn | Permit Intake - Please provide an approved and recorded subdivision survey, verifying the lot(s) of the proposal. You may apply for an official subdivision at https://nola.gov/onestop/building/planning-project/major-or-minor-subdivision/development. |
Zoning | Withdrawn | Please illustrate how parking will be accommodated, as required by the University IZD at one parking space per increase in number of bedrooms. One existing parking space is applied to the former single dwelling. Seven additional bedrooms will require that many additional parking spaces. Parking for a single motor vehicle parking pad needs to be 8.5ft x18ft and offset from side property line by 1 ft. Parking cannot be located between the facade of the structure and the front property line. |
Permit Intake | Resolved | Permit Intake - All contracts shall include both the contractor and owner signature(s), printed name(s), title, and date. |
GIS Addressing | Resolved | added comment on SDREF23-0449 for addressing. SuppM needs to be completed. Emailed. This is only for the LOTS. Separate SuppM needed for the two family structures. |
Plan Review | Resolved | Exterior walls within 3 ft of the property line must be fire rated 1 hour. New windows less than 3 ft from property lines must be protected with 1 hour window systems or fire shutters. |
Zoning | Resolved | Please revise site plan to remove the formerly proposed interior lot line. |