| Plan Review | Resolved | Plan Review-
This project has been reviewed by Warren E. Jones, PE. Any questions, more information needed, or for digital document correspondence, email warren.jones@nola.gov or call (504) 658-7121.
|
| Plan Review | Resolved | Plan Review-
GENERAL NOTES:
1. You can upload documents, written responses to review comments, etc. to the OneStop website.
2. For assistance uploading files, go to https://nola.gov/onestop/help-with-the-one-stop-app/monitoring-and-udating-permits/ and select FAQ “Can I add documents after my application is submitted?”
3. If you upload any documents to OneStop, please notify your plan reviewer by email.
4. Do NOT mix construction plans with letters or other text documents; upload as separate PDF files.
5. Combine multiple plan sheets into a single PDF file.
6. All written responses to review comments must be on letterhead and signed and sealed by the design professional of record (if applicable.)
|
| Plan Review | Resolved | Plan Review-
GENERAL NOTE:
The 2015 International Residential Code (“2015 IRC”) applies to one and two-family dwellings not more than
three stories above grade plane, and their accessory structures. Unless noted otherwise, all review comments and citations reference the 2015 IRC, including all relevant subsections.
|
| Plan Review | Resolved | Approval from the Sewerage and Water Board is required. Submit plumbing riser diagram and a copy of the floor plan directly to Sewerage and Water Board (504-585-2160/ hblancq@swbno.org/jarnold@swbno.org.) Upon approval, notify plan reviewer and provide a copy of the SWBNO stamped riser diagram to this office. |
| Plan Review | Resolved | Plan Review-
New or renovated driveways, sidewalks or curb cuts (including patches and repairs), require approval from the Department of Public Works. Site plan indicating location of the planned improvements must be submitted to DPW.
For more information including a DPW driveway/curb cut permit application, fee schedule and sample standard drawing, go to https://www.nola.gov/onestop/building/street/driveway-sidewalk-cut-permit or contact DPW at (504) 658-8040.
|
| Plan Review | Resolved | Plan Review-
Provide insulation as required by 2015 IRC, Section 1102 (Note: Typ. ceiling/wall/floor values are R-30/R-13/R-13 respectively). Please verify. |
| Plan Review | Resolved | Plan Review-
Where toilet rooms and bathrooms are mechanically ventilated, the ventilation equipment shall vent directly to the exterior and be installed in accordance with 2015 IRC, Section 1507. Please confirm. |
| Plan Review | Resolved | Plan Review-
Provide attic ventilation as required by 2015 IRC, Sec. R806. (Note: Ridge vents, without vented soffits or other assistance, do not guarantee compliance with code.) Please confirm. |
| Plan Review | Resolved | Plan Review-
Please note that zoning and permit analyst reviews are pending. Additional review comments from those divisions may be forthcoming. |
| Permit Intake | Resolved | Contract value is too low. Contracts need to be at least $100/sf. Anything less than that requires the approval from the Director of Safety & Permits. |
| Permit Intake | Resolved | This property is registered with Orleans Parish Assessor's Office in a business/organization name. Register with the Louisiana Secretary of State or submit a copy of the Articles of Corporate Resolution to show proof of ownership. |
| Floodplain Administration | Resolved | Finished floor elevation requirement +2' NAVD |