Your reference code is

JPZ5RF

Application Summary
Type: Renovation (Non-Structural)
Location: 1804 Seventh St
Property Owner: Thomas Lance F
Description: Renovate existing four-plex. Replacing rotten wood and update all kitchens and baths
Created By: publicwebcrm
Status Information
Name Complete Date
Application Submitted Yes 1/22/2019
Fees
Type Amount Paid
Building $625.00 No
Reviews
Division Status Reviewer
Permit Intake Revisions Needed (10/12/2019) Cynthia Cross
Zoning Revisions Needed (1/29/2019) Todd Breckman
Plan Review Revisions Needed (2/8/2019) Treviall Daniels
Electrical Plan Review Pending (2/4/2019) Okechukwu Obinna
Mechanical Plan Review Revisions Needed (2/4/2019) Rama Bhattacharya
Review Comments
Division Status Comment
Permit Intake Open As the proposed value of work exceeds 50% of the Assessor's assessed value of the structure, the proposed work constitutes a substantial improvement for the purposes of Chapter 78 of the City Code. Please do one of the following: a) provide a Benchmark Certificate or Elevation Certificate to verify that the structure meets the required Advisory Base Flood Elevation; b) submit an appraisal to confirm that the proposed work does not exceed 50% of the value of the existing structure; or c) elevate the entire structure to meet the required elevation. Please contact Floodplain Manager's office with questions or concerns 504-658-7127
Zoning Open This appears to be a renovation of a structure with more units than permitted in this zoning district. The non-conforming use status needs to be confirmed prior to release of permit. Please see the attached application.
Mechanical Plan Review Open Rama Bhattacharya is Mechanical and Plumbing reviewer of this project and can be contacted directly for questions / inquiries at his phone line (504) 658-7121/email address: rpbhattacharya@nola.gov
Mechanical Plan Review Open Mechanical (HVAC): No review is required based on submitted cost estimate is under $20,000.00
Mechanical Plan Review Open Plumbing: Please submit plumbing plans complete with riser diagrams for water supply / distribution / waste / vent / building drainage with their line sizes and trap sizes respectively / fixture schedule / exterior plumbing for drainage / sewerage system, where required prepared and duly stamped by a LA registered professional mechanical engineer for our (S & P) Dept. and SWB reviews.
Mechanical Plan Review Open Plumbing: Contd. You are required to submit plumbing plans / riser diagrams /fixture schedule / counts / trap sizes including grease trap sizes , locations and grease disposal (if applicable) directly to SWB (Mr. Hank Blancq at 504-585-2160 / hblancq@swbno.org) for review / approval. Upon receipt of SWB stamped approval, you are required to forward to us by uploading onto our One Stop website to be received by us and also notifying us by email towards completing issuing your permit.
Plan Review Open This project has been reviewed by Treviall Daniels. For email correspondence, please send to tsdaniels@nola.gov. For the most up-to-date status of your permit application, go to the OneStop website at https://onestopapp.nola.gov, enter your permit number or address, and select “Print Summary”. You can also upload documents, written responses to review comments etc. to the OneStop website. Please note: 1. All written responses to review comments must be on letterhead and signed and sealed by the design professional of record (if applicable.) 2. Do NOT mix construction plans with letters or other text documents; upload as separate PDF files. 3. Combine multiple plan sheets into a single PDF file. 4. For general assistance and FAQ’s regarding the OneStop application, go to https://nola.gov/onestop/help-with-the-one-stop-app/ 5. For assistance uploading files, go to https://nola.gov/onestop/help-with-the-one-stop-app/monitoring-and-updating-permits/ and select FAQ “Can I add documents after my application is submitted?” 6. If you upload any documents to OneStop, please notify your plan reviewer by email. 7. For specific questions with a particular department please email to: Safety & Permit and Zoning contact Todd Breckman, twbreckman@nola.gov; Electrical Plan Review contact Obinna Okechukwu, obokechukwu@nola.gov; Mechanical Plan Review contact Rama Bhattacharya, rpbhattacharya@nola.gov.
Plan Review Open Please Note: Please have the Plumbing Riser Diagram and/or proposed Grease trap information submitted to the Sewerage and Water Board of N.O. for approval. You can contact the SWB Plumbing department at (504) 585-2160 or planreview@swbno.org for further information. Please notify plan reviewer once diagram has been submitted.
Plan Review Open As the proposed value of work exceeds 50% of the Assessor's assessed value of the structure, the proposed work constitutes a substantial improvement for the purposes of Chapter 78 of the City Code. Please do one of the following: a) provide a Benchmark Certificate or Elevation Certificate to verify that the structure meets the required Advisory Base Flood Elevation and indicate the BFE on the plans; b) submit to the Damage Assessment process to confirm that the proposed work does not exceed 50% of the appraised value of the existing structure; or c) elevate the entire structure to meet the required elevation or d) submit a letter from: Louisiana Office of Historic Preservation, Capitol Annex Building, 1051 North Third Street, Baton Rouge, Louisiana 70802. Phone: (225) 342-8160.
Plan Review Open Please provide a Site Plan showing ALL setbacks with dimensions to property lines and buildings on adjacent properties to comply with Sec. 107.2.5 of IBC 2015.
Plan Review Open Please provide a floor plan / sketch of the entire building and the work area(s). (show smoke and carbon detectors, fire extinguishers, new window locations, indicated work area(s), and other update specifics, if applicable). Identify the scope of work on the drawings.
Plan Review Open Approval from the State Fire Marshal is required. Please contact the State Fire Marshal’s office at 8181 Independence Blvd., Baton Rouge, LA 70806, (225) 925-4920 / 800-256-5452 or 1450 Poydras St., Suite 1500, New Orleans, LA 70112, (504) 568-8506.
Plan Review Open In Group R-2 occupancies, portable fire extinguishers shall be required in each dwelling unit, and where required by IFC, having a minimum rating of 1-A:10-B:C. Please verify.
Plan Review Open The walls and ceiling/floor assemblies separating the units shall have a 1 hour fire separation. Please verify compliance.
Permit Intake Open Please provide a copy of a detailed contract that includes an itemized description of the work being performed, including fair market value of materials and labor. The contract shall include both the contractor and owner signature(s), printed name(s), titles, and date.
Inspections
Type Date Status
Final Building C/O Unscheduled Unscheduled
General Inspection Unscheduled Unscheduled
Rough Framing Unscheduled Unscheduled
Inspection Correction Items
Contractors
Name License
LA Construction Company LLC
Details
Name Value
Expected Project Completion Date 7/22/2019
Will any portion of the sidewalk be repaired? No
Total project sq ft > 40,000? No
Site area > 1 Acre? No
Footprint >5,000 sq ft? No
Proposed Use Multi-Family Dwelling (Three Units and Above)
Existing Use Multi-Family Dwelling (Three Units and Above)
Will there be work on the exterior of the building? Yes
Construction Type Not Applicable
Existing Building Area (ft²) 3500
Construction Value 113000
Kitchen Added No
Number of Bathrooms 8.00
Number of Bedrooms 8
Total Number of Units 4
Square 256
Addresses 1804 Seventh St
Parcel Tax Bill Numbers 412200607
FEMA Zone 10770
Zoning HU-RD2
Subdivision CENTRAL CITY
Is In Neighborhood Conservation District Yes
Is In Vieux Carré No
Is In Historic District No
Does Structure Encroach / Overhang Sidewalk or Public ROW No
Bed Rooms in New Units 0.00
Sale or Rent N/A
Price of Proposed Units 0.00
Number of Proposed New Units 0
Current Rental Price 800.00
Current Number of Units 4
Number of Bed Rooms per Dwelling 2 Bedroom