Your reference code is

GGW2RE

Application Summary
Type: Renovation (Non-Structural)
Location: 2504 Conti St
Property Owner: Elridge Moore
Description: Convert two family into single family. Gut and reconfigure floor plan (Interior walls are non load bearing). Install new plumbing, HVAC, electrical, flooring, framing, insulation, drywall, cabinets, doors, painting, millwork and hardware.
Created By: publicwebcrm
Status Information
Name Complete Date
Application Submitted Yes 7/15/2018
Application Review Yes 8/8/2018
Zoning Review Yes 8/8/2018
Plan Review Yes 8/8/2018
Permit Approved Yes 8/8/2018
Permit Issued Yes 8/8/2018
Fees
Type Amount Paid
Building $375.00 Yes
Reviews
Division Status Reviewer
Permit Intake Complete (8/8/2018) Treviall Daniels
Zoning Complete (7/16/2018) Zachary Smith
Plan Review Complete (8/8/2018) Treviall Daniels
Review Comments
Division Status Comment
Plan Review Open This project has been reviewed by Treviall Daniels. For email correspondence, please send to tsdaniels@nola.gov. For the most up-to-date status of your permit application, go to the OneStop website at https://onestopapp.nola.gov, enter your permit number or address, and select “Print Summary”. You can also upload documents, written responses to review comments etc. to the OneStop website. Please note: 1. All written responses to review comments must be on letterhead and signed and sealed by the design professional of record (if applicable.) 2. Do NOT mix construction plans with letters or other text documents; upload as separate PDF files. 3. Combine multiple plan sheets into a single PDF file. 4. For general assistance and FAQ’s regarding the OneStop application, go to https://nola.gov/onestop/help-with-the-one-stop-app/ 5. For assistance uploading files, go to https://nola.gov/onestop/help-with-the-one-stop-app/monitoring-and-updating-permits/ and select FAQ “Can I add documents after my application is submitted?” 6. If you upload any documents to OneStop, please notify your plan reviewer by email. 7. For specific questions with a particular department please email to: Safety & Permit and Zoning contact Edward Horan, ejhoran@nola.gov or Todd Breckman, twbreckman@nola.gov; Electrical Plan Review contact Obinna Okechukwu, obokechukwu@nola.gov; Mechanical Plan Review contact Rama Bhattacharya, rpbhattacharya@nola.gov.
Plan Review Resolved Please submit a plumbing riser diagram. The diagram should be sent to SWBNO for approval. You can contact the SWB Plumbing department at (504) 585-2160 or planreview@swbno.org for further information. Please notify (email) plan reviewer once diagram has been submitted.
Plan Review Resolved Please verify the total amount of square footage, or linear feet for interior and exterior walls, of the structure, if any, which will be demolished, removed, or structurally replaced under this application. Please clearly indicate these values. In addition, if any roof structure is to be replaced, please identify the area of roof to be replaced. If any exterior walls are to be replaced (even if rebuilt in place) or demolished and rebuilt, please clearly specify a) the linear footage in question AND b) clearly identify the location of this work on the site plan and floor plan with a clear, labeled, and defined hatch pattern.
Plan Review Withdrawn It appears that interior structural walls were removed. Please provide rafter layout with size and spacing.
Plan Review Resolved Please provide a floor plan / sketch of the entire building and the work area. (show smoke and carbon detectors, new window locations, indicated work area(s), and other update specifics, if applicable). Provide an existing and proposed floor plan for the entire building. Identify the scope of work on the drawings.
Plan Review Resolved As the proposed value of work exceeds 50% of the Assessor's assessed value of the structure, the proposed work constitutes a substantial improvement for the purposes of Chapter 78 of the City Code. Please do one of the following: a) provide a Benchmark Certificate or Elevation Certificate to verify that the structure meets the required Advisory Base Flood Elevation; b) submit to the Damage Assessment process to confirm that the proposed work does not exceed 50% of the appraised value of the existing structure; or c) elevate the entire structure to meet the required elevation or d) submit a letter from: Louisiana Office of Historic Preservation, Capitol Annex Building, 1051 North Third Street, Baton Rouge, Louisiana 70802. Phone: (225) 342-8160
Permit Intake Resolved Please provide a copy of the detailed signed construction contract including the name and license number of the contractor.
Inspections
Type Date Status
Final Building C/O 3/27/2019 10:00 AM Passed
General Inspection Unscheduled Unscheduled
Rough Framing 1/2/2019 2:00 PM Passed
Inspection Correction Items
Contractors
Name License
Construction Specialist Group LLC
Details
Name Value
Expected Project Completion Date 12/15/2018
Will any portion of the sidewalk be repaired? No
Total project sq ft > 40,000? No
Site area > 1 Acre? No
Footprint >5,000 sq ft? No
Proposed Use Single Family Dwelling
Existing Use Two Family Dwelling
Will there be work on the exterior of the building? No
Construction Type Site Built
Existing Building Area (ft²) 1728
Construction Value 62600
Kitchen Added Yes
Number of Bathrooms 2.00
Number of Bedrooms 3
Total Number of Units 2
Parcel ID Numbers 2504-CONTIST
Square 329
Addresses 2504 Conti St
Parcel Tax Bill Numbers 206203420
FEMA Zone 10296
Historic District Name Mid-City
Zoning HU-RD2
Subdivision TULANE - GRAVIER
Is In Neighborhood Conservation District Yes
Is In Vieux Carré No
Is In Historic District Yes
Does Structure Encroach / Overhang Sidewalk or Public ROW No
Bed Rooms in New Units 3.00
Sale or Rent N/A
Price of Proposed Units 0.00
Number of Proposed New Units 1
Current Rental Price 0.00
Current Number of Units 2
Number of Bed Rooms per Dwelling 2 Bedroom