| Your reference code is L0SRHA |
| Type: | Renovation (Structural) |
| Location: | 5926 Tchoupitoulas St |
| Property Owner: | Sarah Ockuly |
| Description: | Renovate existing single-family main house and rebuild rear one-bedroom apartment building as per plans. |
| Created By: | publicwebcrm |
| Name | Complete | Date |
| Application Submitted | Yes | 8/3/2017 |
| Application Review | Yes | 9/27/2017 |
| Zoning Review | Yes | 9/27/2017 |
| Plan Review | Yes | 9/27/2017 |
| Permit Approved | Yes | 11/2/2017 |
| Permit Issued | Yes | 11/2/2017 |
| Inspections Finaled | Yes | 1/31/2023 |
| Certificate of Occupancy | Yes | 1/31/2023 |
| Type | Amount | Paid |
| Building | $840.00 | Yes |
| Building | $40.00 | Yes |
| Building Plan Review | $8.00 | Yes |
| Building Plan Review | $156.00 | Yes |
| Division | Status | Reviewer |
| Permit Intake | Complete (9/27/2017) | Edward J Horan |
| Zoning | Complete (9/27/2017) | Edward J Horan |
| Plan Review | Complete (9/27/2017) | Erin Guerra |
| Plan Review Letter | Complete (8/22/2017) | Gilda Theriot |
| Division | Status | Comment |
| Plan Review | Withdrawn | Each building should have a separate single-family permit. (Main House under this permit, apartment building under separate permit) |
| Permit Intake | Resolved | Please submit a detailed and signed contract/cost estimate for the work to be performed, including labor. |
| Zoning | Resolved | Please submit documentation proving that the legal non-conforming use as a secondary principal structure has been retained for the rear structure. |
| Plan Review | Withdrawn | Please submit a complete set of plans of the main house only. |
| Plan Review | Withdrawn | Please verify the total amount of square footage of the structure, if any, which will be demolished, removed, or structurally replaced under this application. Please clearly indicate these values. In addition, if any roof structure is to be replaced, please identify the area of roof to be replaced. If any exterior walls are to be replaced (even if rebuilt in place) or demolished and rebuilt, please clearly specify a) the linear footage in question AND b) clearly identify the location of this work on the site plan and floor plan with a clear, labeled, and defined hatch pattern. |
| Plan Review | Resolved | Mechanical units shall be placed 3ft from side property lines and 5ft from the rear property line. Please relocate or verify clearance for apartment building A/C unit. |
| Plan Review | Resolved | Please submit a plumbing riser diagram in accordance with the 2016 emergency provision in the State of Louisiana Uniform Construction Code Council. Diagram will be sent to SWBNO for approval. |
| Plan Review | Resolved | remove hdlc fee - under demo permit |
| Plan Review | Resolved | This project has been reviewed by Erin Guerra. For email correspondence, please send to emguerra@nola.gov. Note: Please make sure to email the reviewer if you upload any documents on OneStop. |
| Type | Date | Status |
| Final Building C/O | 3/5/2019 9:00 AM | Passed |
| Foundation | Unscheduled | Unscheduled |
| General Inspection | 11/17/2017 1:30 PM | Passed |
| Rough Framing | 2/15/2018 10:00 AM | Passed |
| Name | License |
| Brian Gille Architects, Ltd | |
| Robert A Bouchon Consulting Engineer LLC | |
| R Heath Neill & Co Contracting LLC |
| Name | Value |
| Construction Type | Site Built |
| Construction Value | 163162 |
| Existing Building Area (ft²) | 1218 |
| Existing Use | Two Family Dwelling |
| Proposed Use | Two Family Dwelling |
| Footprint >5,000 sq ft? | No |
| Site area > 1 Acre? | No |
| Total project sq ft > 40,000? | No |
| Will any portion of the sidewalk be repaired? | No |
| Expected Project Completion Date | 2/15/2018 |
| Total Number of Units | 2 |
| Number of Bedrooms | 3 |
| Number of Bathrooms | 3.00 |
| Kitchen Added | No |
| Parcel Tax Bill Numbers | 615100902 |
| Addresses | 5926 Tchoupitoulas St |
| Square | 4B |
| Parcel ID Numbers | 5926-TCHOUPITOULASST |
| Elevation Requirement | +11.95' NAVD |
| Is In Historic District | Yes |
| Is In Vieux Carré | No |
| Is In Neighborhood Conservation District | Yes |
| Subdivision | WEST RIVERSIDE |
| Zoning | HU-RD2 |
| Historic District Name | Uptown |
| FEMA Zone | 10770 |
| Does Structure Encroach / Overhang Sidewalk or Public ROW | No |