| Permit Intake | Open | Please submit a detailed and signed contract/cost estimate for the work to be performed, including labor. |
| Permit Intake | Open | A Benchmark Certificate is required for this permit application. The Benchmark Certificate must bear the live seal of a Louisiana registered land surveyor and dated within the last six (6) months. This must be on the Safety & Permits three-part form dated September 30, 2016. |
| Zoning | Open | Please clarify the total number of units that currently exist on the site. |
| Plan Review | Open | This project has been reviewed by Treviall Daniels. Please reach him at 658-7129 if you have any questions. For email correspondence, please send to tsdaniels@nola.gov
Note: Please make sure to email the reviewer if you upload any documents on OneStop.
|
| Plan Review | Open | Plumbing Riser Diagram has been sent to Sewerage and Water Board of New Orleans for their review. You can contact the SWB Plumbing department at (504) 585-2160 or planreview@swbno.org for further information. |
| Plan Review | Resolved | Please revise Construction Documents to properly reflect the required elevation for the structure so that it complies with the BFE/ABFE requirements set forth in Section 1612.5 of the IBC 2012 ed. and Section 106.1 of the Amendments to the IBC 2012 ed. Please graphically show where BFE will occur on elevated-view drawings. If the BFE is n/a, provide elevation information from an elevation certificate. Numbers shown on plans should be referenced from such certificate. |
| Plan Review | Resolved | Please verify the total amount of square footage, or linear feet for interior and exterior walls, of the structure, if any, which will be demolished, removed, or structurally replaced under this application. Please clearly indicate these values. In addition, if any roof structure is to be replaced, please identify the area of roof to be replaced. If any exterior walls are to be replaced (even if rebuilt in place) or demolished and rebuilt, please clearly specify a) the linear footage in question AND b) clearly identify the location of this work on the site plan and floor plan with a clear, labeled, and defined hatch pattern. |
| Plan Review | Resolved | Plumbing is not allowed to be installed below base flood. Please verify no new plumbing will occur below base flood. Plumbing fixtures shall be located at or above BFE. Exemption: Plumbing fixtures are permitted below BFE provided that they are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding. |
| Plan Review | Resolved | Subject to the approval of the building official, the use or occupancy of existing buildings shall be permitted to be changed and the building is allowed to be occupied for purposes in other groups without conforming to all the requirements of this code for those groups, provided the new or proposed use is less hazardous, based on life and fire risk, than the existing use. IBC 2012 Section 3408 |