| Your reference code is ZD1835 |
| Type: | Renovation (Non-Structural) |
| Location: | 3500 Garden Oaks Dr, Building No. 24 |
| Property Owner: | ACZS LLC |
| Description: | Non-Structural Renovation of Multi-Family Housing Units. Exterior: Removal of breezeway roof, exterior stairs, and siding. Install new siding. Interior: 4 total existing Units. Remodel of 4 existing single floor units (F Type). 4 units total after construction. |
| Created By: | jrcecil |
| Name | Complete | Date |
| Application Submitted | Yes | 12/30/2013 |
| Zoning Review | Yes | 1/2/2014 |
| Plan Review | Yes | 1/2/2014 |
| Type | Amount | Paid |
| Building | $495.00 | No |
| Building Plan Review | $87.00 | No |
| Division | Status | Reviewer |
| Permit Intake | Complete (1/7/2014) | Wheeler Manouchehri |
| Zoning | Revisions Needed (1/7/2014) | Wheeler Manouchehri |
| Plan Review | Revisions Needed (2/11/2014) | Zachary Smith |
| Division | Status | Comment |
| Zoning | Open | A site plan review is required by the City Planning Commission, as per Article 18 of the Comprehensive Zoning Ordinance. |
| Plan Review | Open | Building #24 - Units F |
| Plan Review | Open | 1. – This project has been reviewed by Zachary Smith. Please reach him at 658-7114 if you have any questions. For email correspondence, please send to zrsmith@nola.gov. 2. – Architectural Plans Required: One set of complete DIGITAL plans of the building which completely detail the work must be submitted with the digital stamped Seal of a Louisiana registered Architect or Civil Engineer as per Section R106.1 of the IRC 2009 ed. 3. – Please provide layouts for the building. Unit plans are provided, but the arrangement of the units into each building is unclear. The exiting arrangements are unclear as well as the wall conditions between units. 4. – Please provide further clarification for the level of Alteration as it relates to IEBC 2009. It appears that several units comprise Level 2 and Level 3 alterations. 5. – Please provide clarification of the cost of work for each structure as it relates to the pre-Katrina value of each structure. 6. - In wind borne debris regions, glazing in buildings shall be impact resistant or protected with an impact resistant covering meeting the requirements of Section 1609.1.2. IBC 2009 ed. Please provide evidence of compliance. 7. – The typical/general details for fire separation between units are unclear. Please provide clarification of rating and provide evidence of compliance for the wall and ceiling assemblies. (UL rating, etc) 8. – The separation between units is unclear. Please provide clarification. 9. – An approved single-station or multiple-single station smoke alarms shall be installed within Groups R-2, R-3 and R-4 occupancies on the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms, in each room used for sleeping purposes, and each story within the dwelling unit, IBC 2009, Section 907.2.11.2 |
| Plan Review | Resolved | Mechanical Review: completed |
| Plan Review | Open | Electrical comments: --1) Please note all wirings shall be as per NEC 2011 edition. --2) Your plans are missing these informations: RISER DIAGRAMS and PANEL SCHEDULES. Please provide. --3) All receptacles in all apartment units shall be listed tamper-resistant as per NEC 2011 Art. 406.13. --4) Please indicate the lighting and power circuits that need to be arc-fault breakers in the all apartment units as per NEC 2011 Art. 210.12(A). |
| Type | Date | Status |
| Final Building C/O | Unscheduled | Unscheduled |
| General Inspection | Unscheduled | Unscheduled |
| Rough Framing | Unscheduled | Unscheduled |
| Name | License |
| Lance Malley |
| Name | Value |
| FEMA Zone | A2 |
| Subdivision | TALL TIMBERS - BRECHTEL |
| Zoning | RM-4 |
| Is In Neighborhood Conservation District | No |
| Is In Vieux Carré | No |
| Is In Historic District | No |
| Proposed Use | Multi-Family Dwelling (Three Units and Above) |
| Existing Use | Multi-Family Dwelling (Three Units and Above) |
| Number of Floors | 2 |
| Construction Value | 86636 |
| Total Number of Units | 4 |
| Kitchen Added | No |
| Square | D |
| Addresses | 3500 Garden Oaks Dr |
| Parcel Tax Bill Numbers | 513615111-0001 |