Your reference code is

ZD1835

Application Summary
Type: Renovation (Non-Structural)
Location: 3500 Garden Oaks Dr, Building No. 24
Property Owner: ACZS LLC
Description: Non-Structural Renovation of Multi-Family Housing Units. Exterior: Removal of breezeway roof, exterior stairs, and siding. Install new siding. Interior: 4 total existing Units. Remodel of 4 existing single floor units (F Type). 4 units total after construction.
Created By: jrcecil
Status Information
Name Complete Date
Application Submitted Yes 12/30/2013
Zoning Review Yes 1/2/2014
Plan Review Yes 1/2/2014
Fees
Type Amount Paid
Building $495.00 No
Building Plan Review $87.00 No
Reviews
Division Status Reviewer
Permit Intake Complete (1/7/2014) Wheeler Manouchehri
Zoning Revisions Needed (1/7/2014) Wheeler Manouchehri
Plan Review Revisions Needed (2/11/2014) Zachary Smith
Review Comments
Division Status Comment
Zoning Open A site plan review is required by the City Planning Commission, as per Article 18 of the Comprehensive Zoning Ordinance.
Plan Review Open Building #24 - Units F
Plan Review Open 1. – This project has been reviewed by Zachary Smith. Please reach him at 658-7114 if you have any questions. For email correspondence, please send to zrsmith@nola.gov. 2. – Architectural Plans Required: One set of complete DIGITAL plans of the building which completely detail the work must be submitted with the digital stamped Seal of a Louisiana registered Architect or Civil Engineer as per Section R106.1 of the IRC 2009 ed. 3. – Please provide layouts for the building. Unit plans are provided, but the arrangement of the units into each building is unclear. The exiting arrangements are unclear as well as the wall conditions between units. 4. – Please provide further clarification for the level of Alteration as it relates to IEBC 2009. It appears that several units comprise Level 2 and Level 3 alterations. 5. – Please provide clarification of the cost of work for each structure as it relates to the pre-Katrina value of each structure. 6. - In wind borne debris regions, glazing in buildings shall be impact resistant or protected with an impact resistant covering meeting the requirements of Section 1609.1.2. IBC 2009 ed. Please provide evidence of compliance. 7. – The typical/general details for fire separation between units are unclear. Please provide clarification of rating and provide evidence of compliance for the wall and ceiling assemblies. (UL rating, etc) 8. – The separation between units is unclear. Please provide clarification. 9. – An approved single-station or multiple-single station smoke alarms shall be installed within Groups R-2, R-3 and R-4 occupancies on the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms, in each room used for sleeping purposes, and each story within the dwelling unit, IBC 2009, Section 907.2.11.2
Plan Review Resolved Mechanical Review: completed
Plan Review Open Electrical comments: --1) Please note all wirings shall be as per NEC 2011 edition. --2) Your plans are missing these informations: RISER DIAGRAMS and PANEL SCHEDULES. Please provide. --3) All receptacles in all apartment units shall be listed tamper-resistant as per NEC 2011 Art. 406.13. --4) Please indicate the lighting and power circuits that need to be arc-fault breakers in the all apartment units as per NEC 2011 Art. 210.12(A).
Inspections
Type Date Status
Final Building C/O Unscheduled Unscheduled
General Inspection Unscheduled Unscheduled
Rough Framing Unscheduled Unscheduled
Inspection Correction Items
Contractors
Name License
Lance Malley
Details
Name Value
FEMA Zone A2
Subdivision TALL TIMBERS - BRECHTEL
Zoning RM-4
Is In Neighborhood Conservation District No
Is In Vieux Carré No
Is In Historic District No
Proposed Use Multi-Family Dwelling (Three Units and Above)
Existing Use Multi-Family Dwelling (Three Units and Above)
Number of Floors 2
Construction Value 86636
Total Number of Units 4
Kitchen Added No
Square D
Addresses 3500 Garden Oaks Dr
Parcel Tax Bill Numbers 513615111-0001