Your reference code is

SDYRJQ

Application Summary
Type: Renovation (Non-Structural)
Location: 3736 Gentilly Blvd
Property Owner:
Description: Remove and replace ADA accessible ramp and other site work as per plans.
Created By: eljohnson
Status Information
Name Complete Date
Application Submitted Yes 9/18/2012
Application Review Yes 11/12/2012
Zoning Review Yes 11/12/2012
Plan Review Yes 11/12/2012
Permit Approved Yes 11/12/2012
Permit Issued Yes 11/12/2012
Certificate of Occupancy Yes 10/16/2013
Fees
Type Amount Paid
Building $235.00 Yes
Building Plan Review $60.00 Yes
Reviews
Division Status Reviewer
Zoning Approved (9/19/2012)
Plan Review Complete (11/12/2012)
Permit Intake Complete (11/12/2012)
Review Comments
Division Status Comment
Permit Intake Resolved Please provide the name and state license number of the General Contractor for this project, once selected.
Permit Intake Withdrawn All public projects require submission of the signed, recorded contract in order to calculate the appropriate fees. Please provide a copy of the construction contract once it has been awarded and subsequently recorded with the Registrar of Conveyances.
Plan Review Open Approval from the State Fire Marshal is required. Please contact the State Fire Marshal’s office at 8181 Independence Blvd., Baton Rouge, LA 70806, (225) 925-4920 / 800-256-5452 or 1450 Poydras St., Suite 1500, New Orleans, LA 70112, (504) 568-8506
Plan Review Open Exterior ramps and stairway protection Sec. 1026.6. Exterior ramps and stairways shall be separated from the interior of the building as required in Sec. 1022.1 Openings shall be limited to those necessary for egress from normally occupied spaces.
Plan Review Open Exterior balconies, stairways and ramps shall be located at least 10 feet from adjacent lot lines and from other buildings on the same lot unless the adjacent building exterior walls and openings are protected in accordance with Sec.705 based on fire separation distance. Sec.1027.3, Exit discharge location- IBC 2009 ed.
Plan Review Resolved Electrical Review: All wiring shall be as per NEC 2008 edition from July 7, 2010 onwards. 1. No electrical plans have been submitted. If you are doing any electrical work, please provide details. 2. All electrical wiring shall conform to the requirements of the International Building Code 2009 edition as amended by the National Electrical Code [NFPA -70] and such other applicable safety codes as enforced by the Safety & Permits [New Orleans Amendments to the International Building Code 2009 edition – articles 101.4.1, 106.1, 2701] 3. If total electrical wiring [MATERIAL & LABOR] exceeds $15,000, please provide the following: [New Orleans Amendments to the International Building Code 2009 edition – articles 101.4.1, 106.1, 2701] Two sets of complete Electrical Plans and specifications. Plans shall include details of service, feeders, panel boards, transformers, disconnect switches, lights, receptacles, wires, cables, wiring devices, symbol schedule, fixture schedule, wireways/junction boxes etc. Plans should have SYMBOLS, RISER DIAGRAMS, ABBREVIATIONS, LEGEND, ELECTRICAL NOTES, LIGHTING SCHEDULE, etc. [New Orleans Amendments to the International Building Code 2009 edition Section 106.1.1 – Page 13] a) PANEL SCHEDULE shall provide name, location, voltage, amp, Neutral mounting, enclosure, feed, braches, available Short Circuit currents, AIC rating [fully rated/series rated], access, circuit numbers, number of poles, load description, volt-amps etc. b) The above plans and specifications shall bear a wet [live] seal and signed statement of a Louisiana Registered Electrical Engineer. [New Orleans Amendments to the International Building Code 2009 edition – articles 101.4.1, 106.1, 2701] 4. One line power riser diagrams as well as panel schedules shall provide details of available short circuit currents at service and secondary panels. Please show that interrupting currents of circuit breakers and fuses match with them as per NEC-2008 articles 110.9, 110.10, 240.12, 225.53, 230.82(3), 230.205(B), 240.92(C)(1) and 230.208. 5. If total Electrical Work [MATERIAL & LABOR] done under this permit is less than $15,000, then please provide an Electrical estimate of this job from an electrician who is licensed with the City of New Orleans [New Orleans Amendments to the International Building Code 2009 edition – articles 101.4.1, 106.1, 2701]. The estimate provided shall be written in the following format: a. Written on paper with the letter-head of the electrician or his electrical contracting company. b. Building Permit Number and the location address. c. Actual details of electrical work that will be done under this building permit. d. Estimated Bill shall consist of actual cost estimate of Labor and materials. e. Signature, License Number of the electrician, address, phone number and today’s date. Electrician’s estimate shall describe the actual work and not to refer to any plans, in case the plans do not bear wet seals and signed statement of a Louisiana Registered Electrical Engine
Plan Review Resolved Mechanical work - not required
Inspections
Type Date Status
Final Building C/O 10/7/2013 8:45 AM Passed
Foundation 4/25/2013 12:00 PM Passed
Inspection Correction Items
Contractors
Name License
C G Favret Co Inc
Details
Name Value
Construction Value 35000
Parcel Tax Bill Numbers 38W307318
Addresses 3736 Gentilly Blvd
Parcel ID Numbers 3736-GENTILLYBL
Is In Historic District No
Is In Vieux Carré No
Is In Neighborhood Conservation District No
Zoning RS-1
FEMA Zone B