Your reference code is

D3EVAY

Application Summary
Type: New Construction
Location: 2503 Almonaster Ave
Property Owner: N2H Investments LLC
Description: New construction of SMALL MULTI-FAMILY AFFORDABLE DWELLING as per plans. In accordance with 20.3.SSS of the CZO. Multifamily, two story, 2 beds, 1 full bath, 1 1/2 bath with 931 sq. foot. Built according to submitted plans. Each will have a separate permit. This permit will be for unit 3.
Created By: publicwebcrm
Status Information
Name Complete Date
Application Submitted Yes 6/10/2025
Application Review Yes 12/10/2025
Zoning Review Yes 12/12/2025
Plan Review Yes 12/11/2025
Permit Approved Yes 12/12/2025
Permit Issued Yes 12/26/2025
Inspections Finaled Yes 9/28/2026
SMFA Compliance Yes 9/28/2026
Certificate of Occupancy Yes 9/28/2026
Fees
Type Amount Paid
Building $565.00 Yes
Building Plan Review $101.00 Yes
Reviews
Division Status Reviewer
Permit Intake Complete (6/16/2025) Gloria Mackey
Floodplain Administration Complete (6/11/2025) Louise C Williams
GIS Addressing Complete (12/10/2025) Joseph V Trinh
Parks and Parkways Tree Review Approved (6/23/2025) Lakeisha Jenkins
Zoning Complete (8/22/2025) Kelly Butler
Plan Review Complete (11/10/2025) Dominique L Scott
SWBNO Plumbing Riser Approved (10/27/2025) Kenneth Boissiere
Review Comments
Division Status Comment
GIS Addressing Resolved Zoning Verification or Non-Conforming Use is needed before addressing can be reviewed. Information on what we need and the application process is available at this link:https://nola.gov/next/safety-and-permits/topics/zoning-administration/zoning-verification/
GIS Addressing Resolved Addressing needs to be updated. For this type of property, we use one root address with the Subtype addresses Apt 1A, Apt 1B (First floor) and Apt 2A, Apt 2B (Second Floor), etc. You can also opt to use Apt 101, 102, 201, 202, etc I have attached a form that I need completed. Please complete and return the last page only. The first column of the table on the form is for the current meter addresses at Entergy. Please write them in exactly as Entergy has them. The requested column (second column) is for the new, updated address. The third column is for the respective meter numbers.
Zoning Resolved This appears that it may be a proposal for a small affordable multifamily development; please clarify intent. If so, please review requirements for 20.3.SSS DWELLING, SMALL MULTI-FAMILY AFFORDABLE, per http://czo.nola.gov/Article-20#20-3-SSS. Please contact Kelly Butler for further compliance requirements - kgbutler@nola.gov
Plan Review Withdrawn PLAN REVIEW: This project has been reviewed by Building Plan Reviewer, Dominique Scott. For email correspondence, please send to dominique.scott@nola.gov Note: Please make sure to email the reviewer if you upload any documents on OneStop.
Plan Review Withdrawn PLAN REVIEW: All written responses to review comments must be on a document with a letterhead, signed, and sealed by the design professional of record, or revisions must be made to the stamped plans. "Will comply" by itself will not suffice to resolve any comment.
Plan Review Resolved PLAN REVIEW: The maximum design load for any piling that reaches refusal in a GM-9 area is 4 tons as per table 1811.12.2.3 of the City of New Orleans Amendments to the 2021 IBC and the pile load capacity map at https://www.nola.gov/safety-and-permits/pile-load-capacity-maps/. (NOTE: Your project is located in Area GM-9.) Please revise.
Plan Review Resolved PLAN REVIEW: Please revise the elevation drawings to properly reflect the required elevation for the structure in compliance with the BFE/ABFE requirements. Graphically indicate where the BFE of -2.0' NAVD will occur.
Plan Review Resolved PLAN REVIEW: Provide one access panel for all under-floor spaces. Access panels shall be a minimum 18” x 24” in accordance with 2021 IRC, Sec. R408.4. Please revise.
Plan Review Resolved PLAN REVIEW: Building materials below base flood elevation shall comply with Sec. R322.1.8 IRC 2021 ed. Please verify.
Plan Review Resolved PLAN REVIEW: Plumbing is not allowed to be installed below base flood. Please verify no new plumbing will occur below base flood.
Plan Review Resolved PLAN REVIEW: Two or more buildings on the same lot shall be regulated as separate buildings as per the 2021 IBC, Section 503.1.2. Please provide 6ft between the units (it's currently 4'-9") or provide fire resistance rated at 1-hr with exposure from both sides to one of the buildings.
Plan Review Resolved PLAN REVIEW: New ground based or wall-mounted mechanical equipment (with less than 7 feet of vertical clearance) may be located in an interior side or rear yard and shall be located at least two (2) feet from a rear lot line and two (2) feet from any side lot line, where at least two (2) feet of that distance remains open to the sky. Please revise for the a/c units and include the distances from all property lines and nearby structures.
Plan Review Resolved PLAN REVIEW: Please provide an electrical plan for the overall structure.
Plan Review Resolved PLAN REVIEW: Windows where the bottom exposed edge is less than 36 inches above the plane of the adjacent walking surface of stairways require safety glazing in accordance to 2021 IRC, Section R308.4.6. Please revise.
Plan Review Withdrawn PLAN REVIEW: Provide dimensions of guard openings to verify that such openings shall not allow passage of a 4” sphere in compliance with IRC 2021, Section R312.1.3.
Plan Review Resolved PLAN REVIEW: Please confirm compliance with the 2021 International Energy Conservation Code (2021 IECC) and State amendments adopted on July 1, 2023. Information on Construction Documents (Sec. R103.2) For new construction, additions, or substantial renovation, please provide details on the construction documents (e.g. in table format) including the following information, as applicable: 1. Energy compliance path 2. Insulation material and their R-values 3. Fenestration U-factors and solar heat gain coefficients (SHGC) 4. Area-weighted U-factor and solar heat gain coefficient (SHGC) calculations 5. Mechanical system design criteria 6. Mechanical and service water heating systems and equipment types, sizes, and efficiencies 7. Equipment and system controls 8. Duct sealing, duct, and pipe insulation and location 9. Air sealing details Total Building Performance-Based Compliance Alternative (Sec. R405.2) - Compliance based on total building performance analysis shall meet the requirements of Table R405.2 - Software tools (e.g. RESCheck) used for performance design shall be in accordance with Sec. R405.3.1. o (Note: For more information and downloadable REScheck software, go to https://www.energycodes.gov/rescheck) - For permit application, a report that complies with Sec. R405.3.2.1 - For certificate of occupancy, a compliance report that complies with Sec. R405.3.2.2 Energy Rating Index (ERI) Compliance Alternative (Sec. R406) - Compliance based on Energy Rating Index (ERI) analysis shall meet the requirements of Sec. R406.2, including o ERI requirements of 2021 IECC sections indicated within Table R406.2 o Maximum ERI (per climate zone) of Table R406.5 Prescriptive Compliance Alternative (Sec. R401.2) - Prescriptive compliance alternative requires compliance with Sections R401 thru R404 - Section R402 insulation compliance can be met in one of three ways: o Assembly U-factor compliance per Section R402.1.2 o R-value per Section R402.1.3; or o Total UA compliance per Section R402.1.5
Plan Review Resolved PLAN REVIEW: Please provide Manuals S, D, and J calculations for review.
Plan Review Resolved PLAN REVIEW: Note, blower door test documentation will need to be submitted prior to the closing of a building permit.
Plan Review Resolved PLAN REVIEW: For any NEW/REPLACEMENT/RELOCATED PLUMBING FIXTURES: Submit a floor plan and riser diagram in PDF format for review/approval by SWBNO (Environmental Affairs). Any questions or for more information on the SWBNO backflow prevention program, contact Kenneth Boissiere at kboissiere@swbno.org or 504-585-2160.
Plan Review Resolved PLAN REVIEW: Do you mean to use r-60 for your ceiling insulation value in the RESCheck? (Note, the required value is r-38.)
Inspections
Type Date Status
Residential Final C/O Inspection 8/4/2026 2:00 PM Passed
Foundation Unscheduled Unscheduled
FEMA Compliance 9/22/2026 3:30 PM Passed
Rough Framing 3/31/2026 3:00 PM Passed
Zoning Unscheduled Passed
Inspection Correction Items
Contractors
Name License
AMM Contractor LLC
Details
Name Value
Construction Value 100345
Construction Type Site Built
New Construction/Addition Area(ft²) 931
Number of Floors 2
Foundation Type Pier
Existing Use Vacant Lot
Proposed Use Single Family Dwelling
Footprint >5,000 sq ft? No
Site area > 1 Acre? No
Total project sq ft > 40,000? No
Will any portion of the sidewalk be repaired? No
Expected Project Completion Date 11/30/2025
Commercial Short Term Rental No
Total Number of Units 1
Number of Bedrooms 2
Number of Bathrooms 2.00
Kitchen Added Yes
Number of new Electrical Meters 1
Number of New Gas Meters 1
Dwelling Area (ft2) 931
Parcel Tax Bill Numbers 41066254
Addresses 2501 Almonaster Ave
Lot Number 11-A
Block Number 1389
Square 1389
Elevation Requirement -2.0' N.A.V.D.
Is In Historic District No
Is In Vieux Carré No
Is In Neighborhood Conservation District Yes
Subdivision ST. CLAUDE
Zoning HU-RD2
FEMA Zone AE
Apply Sub-Permit Triggers? No
Does Structure Encroach / Overhang Sidewalk or Public ROW No
Number of Bed Rooms per Dwelling N/A, not a dwelling
Current Number of Units 0
Current Rental Price 0.00
Number of Proposed New Units 1
Price of Proposed Units 0.00
Sale or Rent N/A
Bed Rooms in New Units 0.00
Is this work related to Super Bowl 2025 activities? No