| Residential Final C/O Inspection |
7/22/2026 |
Passed |
- Exterior fire-rated assemblies complete
- Interior fire-rated assemblies complete
- Attic access (min 22"x30" readily accessible), flooring for equipment access
- Check permit placard and photo of City-approved stamped plans, with revisions if needed
- Smoke and/or CO detectors installed
- Special inspections document, if applicable
- Photos taken
- Stairs complete, guards and rails and details correct, 6'-8" clear
- Safety glazing as required in hazardous locations
- Window sill height and size correct per EERO requirements
- Minimum ceiling height of 7'-0"
- Firestopping
- Insulation
- Flood vents for enclosures below BFE, treated below BFE
- Decks as per plans
- Garage separation
- Heat source other than wood burning provided
- Garage door to interior fire rating
- Crawlspace and vents, access
- Requirements if underside of house is used for storage
|
| Residential Final C/O Documents |
|
Not Required |
- CPC requirements met
- BZA requirements met
- Survey submitted and setbacks verified
- HDLC/VCC Final, if applicable
- Grading certificate submitted
- Federal elevation certificate submitted
- Special inspections document, if applicable
- Piling Affidavit (PAF), if applicable
- Blower door testing
- Changes to original drawings require resubmittal
|
| Foundation |
|
Not Required |
- Permit placard and approved stamped plans, including revisions
- Permit info correct
- Plans have been reviewed for special requirements
- Special inspections reports available
- Benchmark certificate
- Height or setback restrictions
- Erosion control
- Footings constructed per plans,check for chimneys or other projections
- Footing is clear of debris
- Reinforcing is placed and correct size, correct lapping
- 3" from earth, 1 1/2" from form
- Footings are stepped if ground slopes more than 1/10
- Minimum spacing between reinforcing bars
- Splices
- Reinforcement clear of debris
- Conduit/pipe protection
- Conduit 1/3 beam (max)
- Surface drainage minimum
- Crawl space vents, openings, access
- Vapor barrier
- Concrete strength, testing information
- Waterproofing and dampproofing
- Cold/hot weather requirements for concrete
- Filed bending of steel
- Photos
|
| FEMA Compliance |
|
Passed |
|
| Rough Framing |
6/2/2026 |
Passed |
- Permit placard and approved stamped plans, including revisions
- Rough-in inspections approved
- Holdowns and hardware, fasteners,strap anchors, fasteners
- Joist bearing, lapping
- Framed openings
- I-joist installations
- Ridges, hips, valleys, rafters
- Rafter notching and borings
- Purlins and struts
- Trusses
- Roof complete and moisture barriers installed
- Penetrations are sealed as required
- Rough-ins not damaging framing w/notching and boring
- Smoke and CO detector wiring installed
- Safety glazing as required in hazardous locations
- Attic access as required
- Sill heights not exceeding EERO requirements, clear width is code compliant
- Stair landings
- Sheathing
- Blocking
- Fasteners, lumber grades, load path, stud sizes, notching
- Fire ratings as required
- Photos
- Ceiling height 7'-6"
|